Product name |
Scanning Laser Range Finder |
Model |
UST-10LX |
Supply voltage |
DC 12V/DC 24V (operation range 10 to 30V ripple within 10%) |
Supply current |
150mA or less (during start up 450mA is necessary.) |
Light source |
Laser semiconductor (905nm), Laser class 1(IEC60825-1:2007) |
Detection range |
0.06m to 10m (white Kent sheet)
0.06m to 4m (diffuse reflectance 10% )
Max. detection distance : 30m |
Accuracy |
±40mm*1 |
Repeated accuracy |
σ<30mm*1 |
Scan angle |
270° |
Scan speed |
25ms (Motor speed 2400rpm) |
Angular resolution |
0.25° |
Start up time |
Within 10 sec (start up time differs if malfunction is detected during start up) |
Input |
IP reset input, photo-coupler input(current 4mA at ON) |
Output |
Synchronous Output, photo coupler open collector output 30VDC 50mA MAX. |
Interface |
Ethernet 100BASE-TX |
LED display |
Power supply LED display(Blue) : Blinks during start up and malfunction state. |
Surrounding intensity |
Less than 15,000lx
Note : Avoid direct sunlight or other illumination sources as it may cause sensor malfunction |
Ambient temperature and humidity |
-10°C to +50°C, below 85%RH(without dew, frost) |
Storage temperature and humidity |
-30°C to +70°C, below 85%RH(without dew, frost) |
Vibration resistance |
10 to 55Hz double amplitude of 1.5mm for 2hrs in each X, Y, and Z direction
55 to 200Hz 98m / s2 sweep of 2min for 1hr in each X,Y and Z direction |
Vibration resistance(Operating) |
55 to 150Hz 19.6m/s2 sweep of 2min for 30min in each X,Y and Z direction |
Shock resistance |
196m/s2 (20G) X,Y and Z direction 10 times. |
EMC standards |
(EMI)
EN61326-1:2013
EN55011:2009 + A1:2010
(EMS)
EN61326-1:2013
EN61000-4-2:2009
EN61000-4-3:2006 + A1:2008 + A2:2010
EN61000-4-4:2012
EN61000-4-6:2009
EN61000-4-8:2010 |
Protective structure |
IP65 |
Weight |
130g(Excluding cable) |
Material |
Front case: Polycarbonate, Rear case: Aluminum |
Dimensions (W×D×H) |
50×50×70mm(sensor only) |
*1. Under the factory standard testing conditions using white Kent sheet.